Search results for "Viscoelastic Substances"
showing 6 items of 6 documents
Special Uses of Viscoelastics
2000
The possibilities of viscoelastic use in phacoemulsification will be outlined in the following figures. Many ophthalmic surgeons apply viscoelastic substances in capsulorhexis to achieve a deep anterior chamber and extend the pupillary space (with a small pupil). Care must be taken during injection so that aqueous is permitted to flow out. When using a paracentesis to inject viscoelastic (Fig. 59), it must be big enough to allow aqueous outflow. For complete aqueous exchange in the anterior chamber, it is advisable to inject the viscoelastic into the opposite chamber angle.
Osmolality of various viscoelastic substances: comparative study.
2000
Abstract Purpose To determine the osmolality of various viscoelastic substances. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, and Institute for Medical Device Testing, Memmingen, Germany. Methods The analysis was carried out according to the European Pharmacopoeia by means of a calibrated osmometer using the freezing-point depression method. Each syringe was analyzed as a duplicate analysis. Results Mean osmolalities (mOsmol/kg) of the sodium hyaluronate viscoelastic substances were Allervisc® 299; Allervisc® Plus 307; Amvisc® Plus 335; AMO Vitrax® 284; Biolon® 279; Dispasan® 311; Dispasan® Plus 314; Healon® 295; Healon GV® 312; Healon®5 322; HYA-Ophtal® 376; M…
Solid state NMR studies of gels derived from low molecular mass gelators
2016
The emergence of NMR crystallography provides a unique opportunity to study solids, gels and xerogels, thereby providing ample information to elucidate molecular packing in the native gel. This review details the importance as well as the application of solid state NMR spectroscopy combined with other analytical tools to study gels derived from low molecular mass organo- and hydrogelators.
General Applications of Viscoelastics
2000
The many and diverse physicochemical characteristics of viscoelastic substances impose both their desired and undesired effects clinically. As there is no single ideal substance to meet clinical stipulations, individual viscoelastic characteristics should be considered with respect to demand. Georg Eisner described viscoelastic agents as a tool for space-occupying measures (in tissues, in space or on surfaces) applied by the use of special techniques (Eisner, 1980; Eisner, 1983). In surgery, viscoelastic substances protect tissues and cells from mechanical trauma, serve to separate tissues, occupy space, break away adhesions, stop bleeding, coat, act as manipulative instruments and move tis…
Removal of Viscoelastic Substances
2000
All viscoelastics should be completely removed from the eye to reduce the likelihood of increased intraocular pressure. Should OVD retention behind the IOL occur, an unstable refraction could result. Residual high molecular viscous substance is transported away through the trabecular meshwork, with delay, possibly resulting in a protracted postoperative IOP increase. To aspirate viscoelastics various techniques as well as instruments with different aspiration/irrigation adjustments have been proposed, a few of which will be described here. Viscoelastic removal involving the simultaneous irrigation and aspiration through a single cannula (Nevyas, 1987) or two separate cannulas (Brauweiler, 1…
Silver-loaded nanoparticles affect ex-vivo mechanical behavior and mineralization of dentin
2019
Background: The aim was to evaluate the effect of silver loaded nanoparticles (NPs) application on the triboscopic, crystallographic and viscoelastic properties of demineralized dentin. Polymethylmetacrylate-based NPs and Ag loaded NPs were applied on demineralized dentin. Material and Methods: Treated and untreated surfaces were probed by a nanoindenter to test viscoelasticity, and by atomic force microscopy to test nanoroughness and collagen fibril diameter. X-ray diffraction and transmission electron microscopy through selected area diffraction and bright-field imaging were also used. Results: Dentin treated with Ag-NPs attained the lowest complex modulus, and the highest tan delta value…